Go Back / Location:Home / Products

DNBSEQ-G400 CoolMPS High-throughput Sequencing Set

CoolMPS High-throughput Sequencing Set(1) is a novel antibody-based sequencing product. The dNTPs of CoolMPS are without fluorescent labeled (called cold dNTPs) which incorporated into the sequencing strand by DNA polymerase, and base calling is achieved by specific binding of fluorescently labeled antibodies. During this process, the incorporated bases are unmodified, ultimately resulting in clearer base calling.


DNBSEQ-G400 CoolMPS High-throughput Sequencing Set

CoolMPS High-throughput Sequencing Set (DNBSEQ-G400RS FCL SE50)

Item No.:1000017992
1000016985

DNBSEQ-G400RS Sequencing Flow Cell

1000017991

CoolMPS High-throughput Sequencing Kit (DNBSEQ-G400RS FCL SE50)

>

CoolMPS High-throughput Sequencing (DNBSEQ-G400RS FCL SE100)

Item No.:1000016933
1000016985

DNBSEQ-G400RS Sequencing Flow Cell


1000016934



CoolMPS High-throughput Sequencing Kit (DNBSEQ-G400RS FCL SE100)


>

CoolMPS High-throughput Sequencing (DNBSEQ-G400RS FCL PE100)

Item No.:1000016935
1000016985

DNBSEQ-G400RS Sequencing Flow Cell

1000016936

CoolMPS High-throughput Sequencing Kit (DNBSEQ-G400RS FCL PE100)

>

CoolMPS High-throughput Sequencing (DNBSEQ-G400RS Small RNA FCL SE50)

Item No.:1000019478
1000016985

DNBSEQ-G400RS Sequencing Flow Cell

1000017991

CoolMPS High-throughput Sequencing Kit (DNBSEQ-G400RS FCL SE50)

1000006387

MGIEasy Wash Buffer For Small RNA Sequencing

>

Features

Labeled antibodies lead to higher signal
Labeled antibodies lead to higher signal
Multiple labels per antibody, stronger signals
No quenching in CoolMPS
No quenching in CoolMPS
Natural base, no “scar” induced quenching
Polymerase provided natural base environment for binding and incorporation, reaction closer to completeness
Polymerase provided natural base environment for binding and incorporation, reaction closer to completeness
Closer to 100% reaction>>Less signal decay>>Great potential for longer reads
Labeled antibodies lead to higher signal
Labeled antibodies lead to higher signal
Multiple labels per antibody, stronger signals
No quenching in CoolMPS
No quenching in CoolMPS
Natural base, no “scar” induced quenching
Polymerase provided natural base environment for binding and incorporation, reaction closer to completeness
Polymerase provided natural base environment for binding and incorporation, reaction closer to completeness
Closer to 100% reaction>>Less signal decay>>Great potential for longer reads

Recommended Applications

Type Part number
Kit name

Pair end sequencing (PE100) for MGI dual index library

1000011532
CPAS Barcode Primer 3
1000016935

CoolMPS High-throughput Sequencing Set (DNBSEQ-G400RS FCL PE100)

Single end sequencing (SE50) for App-A single index library

1000017992

CoolMPS High-throughput Sequencing Set (DNBSEQ-G400RS FCL SE50)

1000012291

High-Throughput Single-End Sequencing Primer

 Kit (App-A)

Single end sequencing (SE100) for App-A single index library


1000016933

CoolMPS High-throughput Sequencing Set (DNBSEQ-G400RS FCL SE100)

1000012291

High-Throughput Single-End Sequencing Primer Kit (App-A)

Pair end sequencing (PE100) for App-A single index library


1000016935

CoolMPS High-throughput Sequencing Set (DNBSEQ-G400RS FCL PE100)

1000004156

High-Throughput Pair-End Sequencing Primer Kit (App-A)

Pair end sequencing (PE100) for App-A dual index library


1000016935

CoolMPS High-throughput Sequencing Set (DNBSEQ-G400RS FCL PE100)

1000004156

High-Throughput Pair-End Sequencing Primer Kit (App-A)

1000014047

High-Throughput Barcode Primer 3 Reagent Kit(App-A)

>

Product Specification

Flow cell
FCL

Read length 

SE50

SE100 PE100
Maximum cycles

70

120 220
Effective reads/flow cell

1500~2000 M

1500~2000 M 1500~2000 M
Data output/flow cell
75~100 Gb 150~200 Gb 300~400 Gb
Q30* >90% >90% >90%
Run time**
~17 H ~30 H ~58 H

*    Effective Reads and Q30 are based on the standard library. These values may vary with various applications.

**   Run time includes DNB loading, sequencing, and data process (Fastq writing). Run time may vary with various instruments.

(1) Unless otherwise informed, CoolMPS sequencing reagents are not available in Switzerland.  


  • Hotline (Global)
    +86-4000-688-114
  • Email
    MGI-service@mgi-tech.com
  • Special Recommendations
  • *For research use only.

    Not for use in diagnostic procedures (except as specifically noted).
Copyright © 2024 All Rights Reserved MGI Tech Co., Ltd. Guangdong ICP 16117185Privacy PolicyLegal NoticesCookie Policy
Our use of cookies
We would like to use necessary cookies to improve your browsing experience and the quality of our website. We would also like to set analytics cookies and advertisement cookies that help us make improvements by measuring how you use our website. Detailed information about the use of cookies on this website and how you can control your consent can be found in our Cookie Policy and Privacy Policy.
Accept only strictly necessary cookiesAccept all cookies