Unleash Your Sequencing Speed
Location:Home / Products

Unleash Your Sequencing Speed

As one of the sequencers with the fastest speed among mid-low throughput in the world, DNBSEQ-G99(1) is developed based on MGI's core DNBSEQ™ sequencing technology, enabled by innovations in biochemistry, optics, fluidics, temperature control, and other core systems. DNBSEQ-G99 is especially applicable for multiple sequencing methods, it only needs 12 hours to finish PE150 sequencing with Q40 data. Different types of flow cells can be selected for sequencing according to the sample quantity.

Request Quote

Features

Features



8 Gb~192 Gb per run                                


Only 12 hrs for PE150 (from loading to FASTQ)                                       

Supports multiple read lengths, including PE50, SE100, PE150, PE300, SE400                             
Applicable to multiple sequencing methods

Performance Parameter

Maximum number of Flow Cells
Lanes/Flow Cell
Flow Cell Type
Reads/Flow Cell*
Supported Read Lengths
Data Output
Q30***
Q40***
Run Time***
2
1
FCS 40 M
App-D PE150
12 Gb~24 Gb
>90%
>85%
~11 h
FCL 80 M
SE100/PE50
8 Gb~16 Gb
>90%
>85%
~5 h
PE150
24 Gb~48 Gb
>90%
>85%
~12 h
App-D SE100
8 Gb~16 Gb
>90%
>85%
~5 h
App-D PE150
24 Gb~48 Gb
>85%
>85%
~12 h
App-D PE300
48 Gb~96 Gb
>85%
>85%
~30 h
SE400
32 Gb~64 Gb
>75%
>70%
~20 h
FCU
160 M
App-D SE100
16 Gb~32 Gb
>90%
>85%
~7 h
App-D PE150
48 Gb~96 Gb
>85%
>85%
~16 h
App-D PE300
96 Gb~192 Gb
>85%
>80%
~35 h

* Effective reads is determined using a standard library. Actual output may vary depending on sample type and library preparation method.

** The percentage of bases above Q30 and run time is the average of an internal standard library over the entire run. The actual performance is affected by factors such as sample type, library quality, and insert fragment length. Only StandardMPS 2.0(SM 2.0) reagents support the generation of Q40 data.

*** The sequencing time is the statistical duration for single flow cell sequencing and dual flow cell simultaneous sequencing.

★ The instrument is equipped with SE50 and PE100 sequencing modes, and the existing reagent kits support SE50 and PE100 read length sequencing.

Note: APP-D has built-in Illumina’s Truseq, Nextera adapters, and MGI adapter, which supporting mixed testing of Illumina’s Truseq, Nextera adapters, and MGI adapter libraries.



Method
Application

Recommended

read length

Recommended

data size

FCS

FCL
FCU

Recommended sample /RUN

Target capture/multiplex PCR
Onco panel
PE100/PE150
Small panel: ~1 Gb/sample
12/FC,24/RUN
24/FC,48/RUN
48/FC,96/RUN


Genetic disease diagnosis small

panel (Thalassemia, deafness, etc.)


PE150
Deafness: ~5 Gb/sample
2/FC,4/RUN
4/FC,8/RUN
9/FC,18/RUN

Thalassemia: ~0.2 M reads/sample

200/FC,400/RUN

400/FC, 800/RUN

800/FC, 1600/RUN

ATOPlex panel (Respiratory, COVID-19, etc.)

PE100/PE150

Respiratory panel: 5M reads/sample

COVID-19 panel: 5M reads/sample

8/FC,16/RUN
16/FC,32/RUN
32/FC,64/RUN
WES
PE150
15 Gb/sample
/
1-2/FC,2-4/RUN
3/FC,6/RUN
Methylation
Onco targeted methylation panel
PE150
~5 Gb/sample
2/FC,4/RUN
4/FC,8/RUN
9/FC,18/RUN
Small genome sequencing
Metagenomics for pathogen detection
SE50/SE100
Meta:20 M reads/sample
/
4/FC,8/RUN
8/FC,16/RUN
Microbial WGS sequencing
PE100/PE150

Single bacterium: ~1 Gb/sample

12/FC,24/RUN
24/FC,48/RUN
48/FC,96/RUN
16S sequencing
PE300
~0.1 M reads/sample
/
640/FC,1280/RUN
640/FC,1280/RUN
Low-pass WGS sequencing
NIPT
SE50
NIPT/PGS:~10 M reads/sample
/
8/FC,16/RUN
16/FC,32/RUN
PGS
SE50
/

Transcriptome sequencing

RNA-Seq
SE50/PE150

Expression profiling: ~25 M/sample

/
3/FC,6/RUN
6/FC,12/RUN
Transcriptome: ~6 Gb/sample
/
4/FC,8/RUN
8/FC,16/RUN
Forensics

DNA signature identification

SE400
~0.8 M reads/sample
/
96/FC,192/RUN
/

Ordering Information


Cat. No Product Name
900-000611-00 DNBSEQ-G99RS
900-000608-00 DNBSEQ-G99ARS
940-002649-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 App-D FCS PE150)
940-001268-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 FCL SE100/PE50)
940-001269-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 FCL PE150)
940-001267-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 App-D FCL SE100)
940-001274-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 App-D FCL PE150)
940-001716-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 App-D FCL PE300)
940-001757-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 FCL SE400)
940-002776-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 App-D FCU SE100)
940-002775-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 App-D FCU PE150)
940-002773-00
DNBSEQ-G99RS High-throughput Sequencing Set (G99 App-D FCU PE300)
940-000624-00
DNBSEQ-G99RS Cleaning Reagent Kit (G99 SM FCL)
UPS
Selected as needed

System Parameter

  • Product Model

    DNBSEQ-G99 (Without Bioinformatics Module)

    DNBSEQ-G99A (With Bioinformatics Module)

    DNBSEQ-G99RS (Without Bioinformatics Module)(1)

    DNBSEQ-G99ARS (With Bioinformatics Module)(1)


    (1) For research use only. Not for use in diagnostic procedures.


(1) Unless otherwise informed, this StandardMPS sequencing reagent is not available in Germany, UK, Sweden, and Switzerland.
  • Hotline (Global)
    +86-4000-688-114
  • Email
    MGI-service@mgi-tech.com
  • Special Recommendations
  • *For research use only.

    Not for use in diagnostic procedures (except as specifically noted).
Copyright © 2025 All Rights Reserved MGI Tech Co., Ltd. Guangdong ICP 16117185Privacy PolicyLegal NoticesCookie Policy
Our use of cookies
We would like to use necessary cookies to improve your browsing experience and the quality of our website. We would also like to set analytics cookies that help us make improvements by measuring how you use our website. Detailed information about the use of cookies on this website and how you can control your consent can be found in our Cookie Policy and Privacy Policy.
Accept only strictly necessary cookiesAccept all cookies