Go Back / Location:Home / Products

DNBSEQ-G99 High-throughput Sequencing Set (RUO)

DNBSEQ-G99 is developed based on MGI’s core DNBSEQ™ sequencing technology,Enabled by innovations in biochemistry, optics, fluidics, temperature control, and other core systems, DNBSEQ-G99 boasts the fastest speed amongst all medium-to-low throughput sequencers globally. DNBSEQ-G99 is especially applicable for targeted oncology panel sequencing, infectious disease sequencing, oncology methylation sequencing, small whole-genome sequencing, low-depth whole genome sequencing, individual identification, small panel sequencing of 24-28 samples, or whole-exome sequencing of 1-4 samples



DNBSEQ-G99 High-throughput Sequencing Set (RUO)

High-throughput Sequencing Set (G99 SM FCL SE100/PE50)

Item No.:940-000409-00
>

High-throughput Sequencing Set (G99 SM FCL PE150)

Item No.:940-000410-00
>

High-throughput Sequencing Set (G99 SM App-C FCL PE150)

Item No.:940-000413-00
>

DNBSEQ-G99RS Cleaning Reagent Kit (G99 SM FCL)

Item No.:940-000624-00
>

DNBSEQ-G99 Sequencing Flow Cell

Item No.:930-000052-00
>

Features

Rapid sequencing
Rapid sequencing
Only 12 hours for PE150 (from loading to FASTQ).
Flexible throughput
Flexible throughput

Independent loading and running of dual flow cells.

Bioinformatics integrated
Bioinformatics integrated

Option to include built-in bioinformatics module to support sequencing and advanced analysis in a single machine.

Rapid sequencing
Rapid sequencing
Only 12 hours for PE150 (from loading to FASTQ).
Flexible throughput
Flexible throughput

Independent loading and running of dual flow cells.

Bioinformatics integrated
Bioinformatics integrated

Option to include built-in bioinformatics module to support sequencing and advanced analysis in a single machine.

Product Specification

Read length
SE100/PE50
PE150
APP-C SE100***
APP-C PE150
Maximum number 2 2 2 2
Effective reads/flow cell*
80M 80M
80M
80M
Data output
8~16G

24~48G

8~16G

24~48G

Q30***
>90%
>85%
>90%
>85%
Run time(DNB-FQ)
5h

12h

5h

12h

* The effective reads value is obtained according to the operation of a specific standard library, and the actual application library will fluctuate according to the sample type and library construction method.

** The percentage of bases above Q30 and the running time are averaged over the entire run for a particular standard library. The practical application performance is affected by sample type, library quality, insert length and other factors.

*** The APP-C SE100 read length kit will be available in Q1 2023

****The existing kit supports SE50 and PE100 reads, and the instrument does not have SE50 and PE100 sequencing modes.